products
Current Position : Home > Product

BXK-AC series explosion-proof anti-corrosion plugging device (II C. DIP

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1.

Inquiry

Product Description 16A-2 pole, 3 pole

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1.

IEC60079-7. IEC6124-1. EN60079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof mark: Exde II CT6 Gb. DIP21TA, T6

Rated voltage: AC: 110V~130V, 200V~250V, DC: 24V, 36V

Rated current: 16A

Protection level: IP66

Anti-corrosion grade: WF2

Number of poles: 2P. 1P+N+PE. 2P+PE

Inlet thread: 1 G3/4" inlet specification (if you need 2 please specify)

Cable outer diameter: plug and connector for ?8mm~?14mm cable, socket for ?8mm~?18mm cable

Product Description 16A-4 pole

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1

IE60079-7. IEC61241-1. EN60079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof mark: Exde II CT6 Gb. Dipa21TA, T6

Rated voltage: AC: 200V~250V, 380V~415V, 480V~500V, 600V~690V;

Rated current: 16A

Protection level: IP66

Anti-corrosion grade: WF2

Number of poles: 3P+PE

Inlet thread: 1 G3/4" inlet specification (if you need 2 please specify)

Cable outer diameter: plug and connector for ?8mm~?16mm cable, socket for ?8mm~?18mm cable

Product Description 16A-5 pole

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1

IEC60079-7. IEC61241-1. EN60079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof mark: Exde II CT6 Gb. Dipa21ta, T6

Rated voltage: AC: 200V~250V, 380V~415V

Rated current: 16A

Explosion-proof grade: IP66

Anti-corrosion grade: WF2

Number of poles: 3P+N+PE

Inlet thread: 1 G3/4" inlet specification (if you need 2 please specify)

Cable outer diameter: plug and connector for ?8mm~?16mm cable, socket for ?8mm~?18mm cable

Product Description 32A-4 pole, 5 pole

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1

IEC60079-7. IEC61241-1. EN90079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof mark: Exde II CT4 Gb. Dipa21ta, t6

Rated voltage: AC: 200V~250V, 380V~415V, 480V~500V, 600V~690V

Rated current: 32A

Protection level: IP66

Anti-corrosion grade: WF2

Number of poles: 3P+PE. 3P+N+PE

Inlet thread: 1 M40x1.5 inlet specification (if you need 2 please specify)

Cable outer diameter: plug and connector for ?9mm~?19mm cable, socket for ?17mm~?25mm cable

Product Description 63-4 pole, 5 pole

Executive standard: GB3836.1. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1

IEC60079-7 IEC61241-1. EN60079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof standard: Exde II CT4 Gb. Dipa21ta, T6

Rated voltage: AC: 200V~250V, 380V~415V

Rated current: 63A

Protection level: IP66

Anti-corrosion grade: WF2

Number of poles: 3P+PE. 3P+N+PE

Inlet thread: G1 1/2" inlet specification

Cable outer diameter: plug is suitable for ?19mm~?26mm cable, socket is suitable for ?18mm~33mm cable

Product Description 100A/125A-4 pole, 5 pole

Executive standard: GB383601. GB3836.2. GB3836.3. GB12476.1. IEC60079-0. IEC60079-1

IEC60079-7. IEC61241-1. EN60079-0. EN60079-1. EN60079-7. EN61241-1

Explosion-proof mark: Exde II CT4 Gb. DIPA21TA, T6

Rated voltage: AC: 200V~250V, 380V~415V, 480V~500V, 600V~690V

Current Rating: 100A. 125A

Protection level: IP66

Anti-corrosion grade: WF2

Number of poles: 3P+PE. 3P+N+PE

Auxiliary contact: one normally open and one normally closed

Inlet thread: 2 M63x1.5 inlet specifications

Cable outer diameter: the plug is suitable for ?19mm~?28mm cable, the socket is suitable for ?32mm~?44mm cable

Dimensions


 



Inquiry