Scope of application
Applicable to areas 1 and 2 of explosive gas environment;
Applicable to II A, II B explosive gas environment;
Applicable to the temperature group of T1~T4 group;
Widely used in oil exploration, oil refining, chemical, pharmaceutical, military and other hazardous environments and offshore oil platforms, oil tankers and other places.
Technical Parameters
Implementation standards: GB3836.1, GB3836.2, GB3836.3
Explosion-proof mark: Exde II BT4 Gb
Rated voltage: 380V/400V (please specify if there are special requirements)
Protection level: IP65
Anti-corrosion grade: WF1 *WF2
Use category: AC-3, AC-4
Feature of product
The explosion-proof soft starter is used for torque control soft start and soft stop of three-phase squirrel cage asynchronous motor. It is supplied with machine and motor
The soft start and deceleration functions of the protection function, as well as the function of communicating with the control system, its high performance algorithm improves
Equipment availability, security, and ease of use have played a significant role;
The soft starter has an Altistart torque control function that linearly controls the torque supplied to the motor during acceleration and deceleration periods.
Easy to adjust the ramp and starting torque, the wide frequency is suitable for the engine power supply, it can be connected to each motor triangle
The windings are connected in series;
Built-in motor thermal protection, PTC direct thermal protection, start time detection, motor preheating function, underrun in continuous operation and
Overcurrent protection;
The operator panel can be used to modify programming, adjustment or monitoring so that the device can be adjusted and optimized to suit different users.
Claim;
The normal start and heavy load start can be selected according to the load characteristics, and the starting parameters can be set by themselves;
The outer casing is welded by steel plate and the surface is electrostatically sprayed with high voltage.
Selection table |
|||||||
Model specification |
Motor work |
Power (kW) |
Rated current |
(A) |
Introduction device
specification
|
Housing type |
Current outer diameter (mm) |
standard |
Overload |
standard |
Overload |
||||
BQJ-T-7.5 |
7.5 |
5.5 |
17 |
12 |
G1” |
I |
?12-?17 |
BQJ-T-15 |
15 |
11 |
32 |
22 |
|||
BQJ-T-22 |
22 |
18.5 |
47 |
38 |
|||
BQJ-T-30 |
30 |
22 |
62 |
47 |
G1 1/2-2” |
?18-?33 |
|
BQJ-T-45 |
45 |
37 |
88 |
75 |
|||
BQJ-T-55 |
55 |
45 |
110 |
88 |
G2-3” |
II |
?24-?50 |
BQJ-T-75 |
75 |
55 |
140 |
110 |
|||
BQJ-T-90 |
90 |
75 |
170 |
140 |
|||
BQJ-T-110 |
110 |
90 |
210 |
170 |
G3-4” |
III |
?36-?80 |
BQJ-T-132 |
132 |
110 |
250 |
210 |
|||
BQJ-T-160 |
160 |
132 |
320 |
250 |
IV |