Scope of application
Applicable to areas 1 and 2 of explosive gas environment;
Applicable to II A, II B, II C explosive gas environment;
Applicable to areas 21 and 22 of flammable dust environment;
Applicable to T1~T6 (T4) group temperature group;
Widely used in oil exploration, oil refining, chemical, pharmaceutical, military and other hazardous environments and offshore oil platforms, oil tankers and other places.
Feature of product
The outer casing is pressed and formed by ZL 102 aluminum alloy, and the surface is electrostatically sprayed with high pressure;
Built-in AC contactor, thermal relay, self-resetting universal transfer switch, high-breaking miniature circuit breaker with main switch;
It can control the direct start and stop of AC 50Hz, 380V three-phase asynchronous motor, and there is overload and phase failure and no error;
Can be remotely controlled;
Steel pipe or cable wiring can be used;
The maximum current can be up to 63A.
Technical parameters BQC-100-port/port (II B, DIP)
Implementation standards: GB383631, GB3836.2, GB3836.3, GB12476.1
Explosion-proof signs: Exde II BT6 Gb, DIPA21TA, T6 Exde II BT4 Gb, DIPA21TA, T6
Rated voltage: 380V/400V
Rated current: 12A, 18A, 25A, 32A 40A, 50A, 63A
Protection level: IP65
Anti-corrosion grade: WF1 *WF2
Shell material: ZL 102
Built-in components: contactor; thermal relay; terminal block: international well-known brand; BD8060 indicator light; self-reset
Universal transfer switch
In and out of the line direction: down and down
Installation method: hanging type
Note: The remote control function can be added according to user requirements.
Technical parameters BQC100-port/port/K (II B, DIP)
Implementation standards: GB3836.1, GB3836.2, GB3836.3, GB12476.1
Selection
Explosion-proof signs: Exde II BT6 Gb, DIPA21TA, T6 Exde II BT4 Gb, DIPA21TA, T6
Rated voltage: 380V/400V
Rated current: 12A, 18A, 25A, 32A 40A, 50A, 63A
Protection level: IP65
Anti-corrosion rating: WF1 *WF2
Shell material: ZL 102
Built-in components: contactor; thermal relay; terminal block: Weidmüller SAK terminal; BD8060 indicator light; self-reset
Switch
In and out of the line direction: down and down
Installation method: hanging type
Note: You can increase the remote control according to the user's request.
Technical parameters BQC100-port/port N (II B, DIP)
Implementation standards: GB3836.1, GB383632\, GB3836.3, GB1241-1
Explosion-proof signs: Exde II BT6 Gb, DIPA21TA, T6
Rated voltage; 380V/400N
Rated current: 12A, 18A, 25A, 32A
Protection level: IP65
Anti-corrosion grade: WF1 *WF2
Shell material: ZL 102
Built-in components: contactor; thermal relay; terminal block: Weidmüller SAK terminal: BD8060 indicator light; self-recovery
Universal switch
In and out of the line direction: down and down
Installation method: hanging type
Note: The remote control function can be added according to user requirements.
Technical parameters BQC100-port/port/K/N (II B, DIP)
Implementation standards: GB3836.1, GB3836.2, GB3836.3, GB12476.1
Selection table |
|||||
Model specification |
Control motor maximum power (kW) |
Relay setting current adjustment range (A) |
Contactor rated current (A) |
Outlet thread |
Cable outer diameter
(mm)
|
BQC100-12/口 |
5.5 |
7-10(6-10) |
12 |
G1” |
?12 -?17 |
BQC100-18/口 |
7.5 |
12-18(12-16) |
18(17) |
G1” |
?12 -?17 |
BQC100-25/口 |
11 |
16-24 |
25 |
G1” |
?12 -?17 |
BQC100-32/口 |
15 |
23-32(24-32) |
32 |
G1 1/4” |
?15 -23 |
BQC100-40/口 |
18.5 |
30-40(24-40) |
40 |
G1 1/4” |
?15 -?23 |
BQC100-50/口 |
22 |
37-50(40-57) |
50 |
G1 1/2” |
?18 -?33 |
BQC100-63/口 |
30 |
48-65(50-65) |
63(65) |
G1 1/2” |
?18 -?33 |
Electrical schematic